One-Stop-Shop for all your Fire Safety & Protection requirements

Main Office Tel: 021 480 8542

Call-Out (24Hrs): 085 284 5939

3 3

PRODUCTS

FIRE PANELS

Conventional Fire Alarm Equipment

This system has a set amount of zones, ranging from 1 – 20.


Example:
You could have 15 smoke detectors on a zone on the ground floor of a building which could be zone 1. So you would have to search all the rooms on the ground floor to find the detector in fault or in fire.

 

 

 


Addressable Fire Alarm Equipment

This is an intelligent system. In this case the fire panel has a digital screen and will tell you what zone and exactly the location of the detector.


An addressable detector has a unique address (e.g. Number) this number detector gets a location address put into the fire panel when the system is first commissioned.


Example:
So when a detector goes off it will say ground floor, room 4.

This type of system cuts down on time, fault finding and in the event of a fire gives exact location.

 

 

 


Smoke Detectors

Our Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.

 

• Responds well to slow-burning smouldering fires

• Well suited for bedrooms and escape routes

• Unaffected by wind or atmospheric pressure

• Five response modes

• Remote test feature

 


CO/Heat Multisensor Detectors

The CO/Heat Multisensor Detector is good at detecting deep-seated smouldering fires which give off a lot of CO as well as flaming fires. They are ideal for use in hotel bedrooms where steam may be present, dusty environments or even where simulated smoke may be present. 

 

• Responds to smouldering and flaming fires

• Less susceptible to false alarms caused by steam and dust

• Five response modes

• Remote test feature

 

 


Heat Detectors

The CO/Heat Multisensor Detector is good at detecting deep-seated smouldering fires which give off a lot of CO as well as flaming fires. They are ideal for use in hotel bedrooms where steam may be present, dusty environments or even where simulated smoke may be present. 

 

• Responds to smouldering and flaming fires

• Less susceptible to false alarms caused by steam and dust

• Five response modes

• Remote test feature

 

 


Manual Call Point

Safetytech Fire offers a selection of differently coloured call points suitable for a variety of applications such as initiating a hazard rather than a fire alarm.

 

• Flashing LED option to indicate polling

• Plug and play' terminal connections for fast wiring

• Continuity link for wiring test before commissioning

• Reports an alarm in under 0.2 seconds

• Resettable element

 


Open-Area Sounder Beacon

The Open-Area Sounder Beacon is designed for use in indoor and open-areas. When a fire system is being commissioned a 'Magnetic Wand' can be used to adjust and test each sounder locally.

 

• 15 tone pairs

• Individual conrtol of the sounder and beacon

• Volume & tone settings can be selected from the control panel

• Tones can be used for toher purposes in addition to warning of fire, making the device ideal for use in schools etc.

• Soft start option, ideal for hospitals and nursing homes

• Group and global control for increased response time

 


Intelligent Mounting Base

The Mounting Base is a low insertion force base with stainless steel contacts for the detector terminals. XPERT cards are supplied with all bases.

 

• XPERT Addressing

• One way fit

• Locking feature to prevent unauthorised detector removal

 

 

FOR MORE INFORMATION CALL US TODAY 021 480 8542 or 087 924 3112